SA Water Homepage SA Water Homepage
SA Government logo. Link to Ministers' website sa.gov.au - find what you're looking for
SA Water - Developers/Builders - Network Infrastructure Standards
    
Sewer Manual Index
 

Cover Page / Preface
Section B - Contents and Index
Section C - General Information
Section D - Allocation of Space for Services
Section E - References
Section F - Corrosion Protection
Section G - Excavation, Embedment & Trench Fill
Section H - Pipe Laying
Section J - Vents
Section K - Connections
Section L - Maintenance Structures & Inspection Openings
Section M - Standard Submersible Sewage Pumping Stations
Section N - Quick Reference 

PAGE

DRAWING No.

TITLE

Cover Page

   

Preface

   
     

SECTION B

CONTENTS AND INDEX

B

 

Section B Cover Sheet

B1

 

Index

     

SECTION C

GENERAL INFORMATION

C

 

Section C Cover Sheet

C1

96 - 0180 - 01

Underground Services, Protection of Existing Trees/Environment & Dewatering

C2

96 - 0180 - 02

Shoring of Excavations & Use of Explosives

     

SECTION D *

ALLOCATION OF SPACE FOR SERVICES

D

 

Section D Cover Sheet

D1

91 - 0084 - 01B

Allocation of Space for Services in Land Divisions Typical Dimensions - Sheet 1

D2

91 - 0084 - 02C

Allocation of Space for Services in Land Divisions Typical Dimensions - Sheet 2

D3

91 - 0084 - 03

Road Traffic Information Sheet 1

D4

91 - 0084 - 04

Road Traffic Information Sheet 2

D5 

2009 - 31260 Rev 2

Allocation of Space for Services in Land Divisions (with Recycled Water) with light poles located on boundary – Allotments Less than 8 meters wide

     

SECTION E

REFERENCES

E

 

Section E Cover Sheet

E1

96 - 0180 - 03

Australian Standards, SA Water Specifications, Department of Transport specifications

E2

96 - 0180 - 04

List of References and Regulations.

     

SECTION F

CORROSION PROTECTION

F

 

Section F Cover Sheet

F1

96 - 0180 - 05

General Information

     

SECTION G *

EXCAVATION, EMBEDMENT & TRENCH FILL

   

Section G Cover Sheet

G1

02 - 0296 - 01

Installation of Sewer Pipes

G2

02 - 0156 - 01

Trench Excavation & Embedment of Sewers using 10-7 mm Screenings

G3

02 - 0157 - 01

Reinstatement of Road Pavement, Hard Shoulders & Verges in Road Reserves

     

SECTION H *

PIPE LAYING

   

Section H Cover Sheet

H1

96 - 0059 - 01

Water Seals in Branch Sewers

H2

96 - 0059 - 02

Pumping Main Discharge into Access Chamber

H3

02 - 0288 - 01

Railway Crossings

     

SECTION J *

VENTS

J

 

Section J Cover Sheet

J1

94 - 0168 - 01

Siting and Spacing of Induct and Educt Vents for Trunk Sewers

J2

94 - 0168 - 02

General Arrangement of DN 300 Induct Vents off Trunk Sewers

J3

94 - 0168 - 03A

General Arrangement of DN 300 Educt Vents

     

SECTION K *

CONNECTIONS (divided into SET - K1 and SET - K2)

K

 

Section K Cover Sheet

K1

94 - 0164 - 01A

Connection Locations

K2

94 - 0164 - 02A

Inspection Point Details

K3

94 - 0164 - 03A

Single Connections

K4

94 - 0164 - 04A

' Y ' Connections

K5

94 - 0164 - 05A

Connections with Riser off UPVC Sewer

K6

94 - 0164 - 06A

Connections with 'Jump Up' at Boundary IP

K7

94 - 0164 - 08A

Connections with Intermediate Riser

K8

94 - 0164 - 09A

Connections Through Embankment

K9

94 - 0164 - 16A

Connections Left/Right into Access Chambers with/without Large Jump Up

K10

94 - 0164 - 10A

Connections 'Ahead' into Access Chambers with or without Large Jump-Up.

K11

94 - 0164 - 11A

Water Seals on Connections

K12

94 - 0162 - 01C

Connections off DN 375 and Larger VC and RCRJ Trunk Sewers.

K13

94 - 0161 - 01C

Connections off Existing DN 150, 225 and 300 VC Sewers.

K14

94 - 0160 - 01C

Connections off Existing DN 150, 225 and 300 UPVC Sewers.

     

SECTION L *

MAINTENANCE STRUCTURES & INSPECTION OPENINGS (divided into SET - L1 and SET - L2)

L

 

Section L Cover Sheet

L1

94 - 0167 - 01

General Notes

L2

94 - 0167 - 02

Access Chamber and Inspection Opening Locations in Roadways & Easements

L3

94 - 0167 - 03

DN 150 Inspection Openings

L4

94 - 0167 - 04

Typical Construction Details for 900 Internal Diameter Access Chamber

L5

94 - 0167 - 05A

Typical Construction Details for 1050 Internal Diameter Access Chamber.

L6

94 - 0167 - 06A

Typical Construction Details for 1200 Internal Diameter Access Chamber.

L7

94 - 0167 - 07

Construction Details for 1400 Internal Diameter Access Chamber with Conical Top

L8

94 - 0167 - 08

Typical Construction Details for 1500 Internal Diameter 'Control' Access Chamber

L9

94 - 0167 - 09

Bench and Channel Details in Access Chambers for Sewers up to DN 600

L10

94 - 0167 - 10

Channel Configurations in Access Chambers for Sewers up to DN 600

L11

94 - 0167 - 11

Access Chamber with 150 DN External Jump Up

L12

94 - 0167 - 12

Access Chamber with 150 DN Internal Sewer Jump Up

L13
L13A
L13B

94 - 0167 - 13
99 - 0114 - 01
99 - 0115 - 01

Trunk Sewer Access Chamber for 675 and 750 Sewers
Trunk Sewer Maintenance Hole for DN 450 and larger
Trunk Sewer Maintenance Hole for > DN 450 straight through

L14

94 - 0167 - 14

Lightweight Access Chamber for use in Easements with Restricted Access

L15

94 - 0167 - 15

Height and Crossfall Adjustment Details for Access Chamber Slabs

L16

02 - 0289 - 01

Maintenance Shafts Installation

L17

02 - 0290 - 01

Maintenance Shafts with Variable Bends

L18

02 - 0291 - 01

Maintenance Shaft Terminal and End MS with Connections Ahead

     

SECTION M *

STANDARD SUBMERSIBLE SEWAGE PUMPING STATIONS (divided into SET -M1 and SET - M2)

M

 

Section M Cover Sheet

M1

94 - 0163 - 01

Site Arrangement

M2

94 - 0163 - 02

Standard Notes Sheet 1

M3

94 - 0163 - 03

Standard Notes Sheet 2

M4

94 - 0163 - 04

Standard Notes Sheet 3

M5

94 - 0163 - 05

Site Arrangement and Access Where Station Abuts a Public Road

M6

94 - 0163 - 06

Site Arrangement and Access Road Where Station Does Not Abut a Road

M7

94 - 0163 - 07

Plan and Section

M8

94 - 0163 - 08

Electrical Cubicle, Base and Conduit Details

M9

94 - 0163 - 09

ETSA Service and Telemerty Details Including Trenchfill for Electrical Conduits

M10

94 - 0163 - 10

Fence Detail (Typical)

M11

94 - 0163 - 11

DN 40 Water Service

M12

94 - 0163 - 12

Access Roadway, Cross Section and Drainage Details (Typical)

M13

94 - 0163 - 13

Typical Arrangement for Valve Chamber (Non-Trafficable).

M14

94 - 0163 - 14

Typical Arrangement for Valve Chamber With Flow Meter (Non-Trafficable)

M15

 

To be Issued

M16

94 - 0163 - 16

In-Line Stop Valve Assembly for DN 100 to DN 200 Sewage Pumping Mains

M17

94 - 0163 - 17

Pump-out Branch for Sewage Pumping Mains

M18

94 - 0163 - 18

Air Relief Valves for Sewage Pumping Mains

M19

94 - 0163 - 19

Indicator Post and Signs for Sewage Pumping Mains

     

SECTION N

QUICK REFERENCE

N

 

Section N Cover Sheet

N1

 

Quick Reference A - I

N2

 

Quick Reference J - Z


* Large filesizes, please be patient when downloading

Contact Us : Feedback : Web Admin : Disclaimer : Privacy Policy : Minister's Site : Sitemap : Search
Copyright © SA Water, 2004 ABN 69 336 525 019 Last Updated: Saturday, 24 Jul, 2010