|
PAGE |
DRAWING No. |
TITLE |
|
Cover Page |
|
|
|
Preface |
|
|
| |
|
|
|
SECTION B |
CONTENTS AND INDEX |
|
B |
|
Section B Cover Sheet |
|
B1 |
|
Index |
| |
|
|
|
SECTION C |
GENERAL INFORMATION |
|
C |
|
Section C Cover Sheet |
|
C1 |
96 - 0180 - 01 |
Underground Services, Protection of Existing Trees/Environment & Dewatering |
|
C2 |
96 - 0180 - 02 |
Shoring of Excavations & Use of Explosives |
| |
|
|
|
SECTION D * |
ALLOCATION OF SPACE FOR SERVICES |
|
D |
|
Section D Cover Sheet |
|
D1 |
91 - 0084 - 01B |
Allocation of Space for Services in Land Divisions Typical Dimensions - Sheet 1 |
|
D2 |
91 - 0084 - 02C |
Allocation of Space for Services in Land Divisions Typical Dimensions - Sheet 2 |
|
D3 |
91 - 0084 - 03 |
Road Traffic Information Sheet 1 |
|
D4 |
91 - 0084 - 04 |
Road Traffic Information Sheet 2 |
|
D5 |
2009 - 31260 Rev 2 |
Allocation of Space for Services in Land Divisions (with Recycled Water) with light poles located on boundary – Allotments Less than 8 meters wide |
| |
|
|
|
SECTION E |
REFERENCES |
|
E |
|
Section E Cover Sheet |
|
E1 |
96 - 0180 - 03 |
Australian Standards, SA Water Specifications, Department of Transport specifications |
|
E2 |
96 - 0180 - 04 |
List of References and Regulations. |
| |
|
|
|
SECTION F |
CORROSION PROTECTION |
|
F |
|
Section F Cover Sheet |
|
F1 |
96 - 0180 - 05 |
General Information |
| |
|
|
|
SECTION G * |
EXCAVATION, EMBEDMENT & TRENCH FILL |
| |
|
Section G Cover Sheet |
|
G1 |
02 - 0296 - 01 |
Installation of Sewer Pipes |
|
G2 |
02 - 0156 - 01 |
Trench Excavation & Embedment of Sewers using 10-7 mm Screenings |
|
G3 |
02 - 0157 - 01 |
Reinstatement of Road Pavement, Hard Shoulders & Verges in Road Reserves |
| |
|
|
|
SECTION H * |
PIPE LAYING |
| |
|
Section H Cover Sheet |
|
H1 |
96 - 0059 - 01 |
Water Seals in Branch Sewers |
|
H2 |
96 - 0059 - 02 |
Pumping Main Discharge into Access Chamber |
|
H3 |
02 - 0288 - 01 |
Railway Crossings |
| |
|
|
|
SECTION J * |
VENTS |
|
J |
|
Section J Cover Sheet |
|
J1 |
94 - 0168 - 01 |
Siting and Spacing of Induct and Educt Vents for Trunk Sewers |
|
J2 |
94 - 0168 - 02 |
General Arrangement of DN 300 Induct Vents off Trunk Sewers |
|
J3 |
94 - 0168 - 03A |
General Arrangement of DN 300 Educt Vents |
| |
|
|
|
SECTION K * |
CONNECTIONS (divided into SET - K1 and SET - K2) |
|
K |
|
Section K Cover Sheet |
|
K1 |
94 - 0164 - 01A |
Connection Locations |
|
K2 |
94 - 0164 - 02A |
Inspection Point Details |
|
K3 |
94 - 0164 - 03A |
Single Connections |
|
K4 |
94 - 0164 - 04A |
' Y ' Connections |
|
K5 |
94 - 0164 - 05A |
Connections with Riser off UPVC Sewer |
|
K6 |
94 - 0164 - 06A |
Connections with 'Jump Up' at Boundary IP |
|
K7 |
94 - 0164 - 08A |
Connections with Intermediate Riser |
|
K8 |
94 - 0164 - 09A |
Connections Through Embankment |
|
K9 |
94 - 0164 - 16A |
Connections Left/Right into Access Chambers with/without Large Jump Up |
|
K10 |
94 - 0164 - 10A |
Connections 'Ahead' into Access Chambers with or without Large Jump-Up. |
|
K11 |
94 - 0164 - 11A |
Water Seals on Connections |
|
K12 |
94 - 0162 - 01C |
Connections off DN 375 and Larger VC and RCRJ Trunk Sewers. |
|
K13 |
94 - 0161 - 01C |
Connections off Existing DN 150, 225 and 300 VC Sewers. |
|
K14 |
94 - 0160 - 01C |
Connections off Existing DN 150, 225 and 300 UPVC Sewers. |
| |
|
|
|
SECTION L * |
MAINTENANCE STRUCTURES & INSPECTION OPENINGS (divided into SET - L1 and SET - L2) |
|
L |
|
Section L Cover Sheet |
|
L1 |
94 - 0167 - 01 |
General Notes |
|
L2 |
94 - 0167 - 02 |
Access Chamber and Inspection Opening Locations in Roadways & Easements |
|
L3 |
94 - 0167 - 03 |
DN 150 Inspection Openings |
|
L4 |
94 - 0167 - 04 |
Typical Construction Details for 900 Internal Diameter Access Chamber |
|
L5 |
94 - 0167 - 05A |
Typical Construction Details for 1050 Internal Diameter Access Chamber. |
|
L6 |
94 - 0167 - 06A |
Typical Construction Details for 1200 Internal Diameter Access Chamber. |
|
L7 |
94 - 0167 - 07 |
Construction Details for 1400 Internal Diameter Access Chamber with Conical Top |
|
L8 |
94 - 0167 - 08 |
Typical Construction Details for 1500 Internal Diameter 'Control' Access Chamber |
|
L9 |
94 - 0167 - 09 |
Bench and Channel Details in Access Chambers for Sewers up to DN 600 |
|
L10 |
94 - 0167 - 10 |
Channel Configurations in Access Chambers for Sewers up to DN 600 |
|
L11 |
94 - 0167 - 11 |
Access Chamber with 150 DN External Jump Up |
|
L12 |
94 - 0167 - 12 |
Access Chamber with 150 DN Internal Sewer Jump Up |
|
L13 L13A L13B |
94 - 0167 - 13 99 - 0114 - 01 99 - 0115 - 01 |
Trunk Sewer Access Chamber for 675 and 750 Sewers Trunk Sewer Maintenance Hole for DN 450 and larger Trunk Sewer Maintenance Hole for > DN 450 straight through |
|
L14 |
94 - 0167 - 14 |
Lightweight Access Chamber for use in Easements with Restricted Access |
|
L15 |
94 - 0167 - 15 |
Height and Crossfall Adjustment Details for Access Chamber Slabs |
|
L16 |
02 - 0289 - 01 |
Maintenance Shafts Installation |
|
L17 |
02 - 0290 - 01 |
Maintenance Shafts with Variable Bends |
|
L18 |
02 - 0291 - 01 |
Maintenance Shaft Terminal and End MS with Connections Ahead |
| |
|
|
|
SECTION M * |
STANDARD SUBMERSIBLE SEWAGE PUMPING STATIONS (divided into SET -M1 and SET - M2) |
|
M |
|
Section M Cover Sheet |
|
M1 |
94 - 0163 - 01 |
Site Arrangement |
|
M2 |
94 - 0163 - 02 |
Standard Notes Sheet 1 |
|
M3 |
94 - 0163 - 03 |
Standard Notes Sheet 2 |
|
M4 |
94 - 0163 - 04 |
Standard Notes Sheet 3 |
|
M5 |
94 - 0163 - 05 |
Site Arrangement and Access Where Station Abuts a Public Road |
|
M6 |
94 - 0163 - 06 |
Site Arrangement and Access Road Where Station Does Not Abut a Road |
|
M7 |
94 - 0163 - 07 |
Plan and Section |
|
M8 |
94 - 0163 - 08 |
Electrical Cubicle, Base and Conduit Details |
|
M9 |
94 - 0163 - 09 |
ETSA Service and Telemerty Details Including Trenchfill for Electrical Conduits |
|
M10 |
94 - 0163 - 10 |
Fence Detail (Typical) |
|
M11 |
94 - 0163 - 11 |
DN 40 Water Service |
|
M12 |
94 - 0163 - 12 |
Access Roadway, Cross Section and Drainage Details (Typical) |
|
M13 |
94 - 0163 - 13 |
Typical Arrangement for Valve Chamber (Non-Trafficable). |
|
M14 |
94 - 0163 - 14 |
Typical Arrangement for Valve Chamber With Flow Meter (Non-Trafficable) |
|
M15 |
|
To be Issued |
|
M16 |
94 - 0163 - 16 |
In-Line Stop Valve Assembly for DN 100 to DN 200 Sewage Pumping Mains |
|
M17 |
94 - 0163 - 17 |
Pump-out Branch for Sewage Pumping Mains |
|
M18 |
94 - 0163 - 18 |
Air Relief Valves for Sewage Pumping Mains |
|
M19 |
94 - 0163 - 19 |
Indicator Post and Signs for Sewage Pumping Mains |
| |
|
|
|
SECTION N |
QUICK REFERENCE |
|
N |
|
Section N Cover Sheet |
|
N1 |
|
Quick Reference A - I |
|
N2 |
|
Quick Reference J - Z |