PAGE |
DRAWING No. |
TITLE |
|
Cover Page |
|
|
|
Preface |
|
|
| |
|
|
|
SECTION A |
INDEX |
|
A1 |
Sheet 1 |
|
|
A2 |
Sheet 2 |
|
| |
|
|
|
SECTION B * |
EXCAVATION, EMBEDMENT & TRENCH FILL, ANCHOR / THRUST BLOCKS |
|
B |
|
Section B Cover Sheet |
|
B1 |
01 - 0008 - 01B |
Installation of Water Supply Pipes |
|
B2 |
01 - 0010 - 01A |
Embedment of Water Supply Pipes in Road Reserves and Easements Using TS4 Sand |
|
B3 |
01 - 0161 - 01B |
Reinstatement of Road Pavements, Hard Shoulders and Verges in Road Reserves |
|
B4 |
01 - 0162 - 01A |
Reinstatement of Excavations After Bursts or Other Small Scale Repair Works |
|
B5 |
02 - 0292 - 01A |
Soil Classification Guidelines |
|
B6 |
|
Reserved |
|
B7 |
02 - 0293 - 01 |
Thrust Block Details |
|
B8 |
02 - 0294 - 01B |
Thrust and Anchor Blocks |
|
B9 |
02 - 0295 - 01 |
Restrained DI Joint System |
|
B10-B16 |
|
Reserved |
|
B17 |
91 - 0054 - 01G |
Thrust and Anchor Blocks for Various Dead End Types |
| |
|
|
|
SECTION C * |
MAINLAYING |
|
C |
|
Section C Cover Sheet |
|
C1 |
91 - 0055 - 01C |
Sleeving of DICL Pipe Barrels |
|
C2 |
91 - 0056 - 01F |
Corrosion Protection of CI and DICL Fittings for PVC and DICL Pipes |
|
C3 |
91 - 0057 - 01F |
PVC Mains to DN 300 Jointing and Deflection |
|
C4 |
91 - 0058 - 01E |
DICL Mains to DN 750 Jointing and Deflection |
|
C5 |
91 - 0059 - 01G |
Laying Details for Branches off New Mains and Isolating Valve and Below Ground Fire Hydrant Sets on New Mains – PVC and Non Restrained Joint DICL |
|
C6 |
91 - 0059 - 05B |
Laying Details for Branches off New Mains and Isolating Valve and Below Ground Fire Hydrant Sets on New Mains – Restrained Joint DICL |
|
C7 |
91 - 0059 - 02F |
Laying Details for DN100 and DN150 Branches off Existing PVC, AC, CICI and DICL Mains and off Existing Restrained Joint DICL Mains |
|
C8 |
91 - 0059 - 03D |
Laying Details for Branches off Existing MSCL Mains |
|
C9 |
91 - 0059 - 04C |
Laying Details for Branches DN200 and Larger off Existing Restrained Joint DICL Mains (Not Recommended for DN100 and DN150mm Branches) |
|
C10 |
91 - 0090 - 01E |
Standard Chambers for Isolating Valves and Below Ground Fire Hydrants – Sheet 1 in Easements, Tracks and Unsealed Roads Concrete Topstones Applications |
|
C11 |
91 - 0090 - 02E |
Standard Chambers for Isolating Valves and Below Ground Fire Hydrants – Sheet 2 in Improved Roads and Footpaths Street Box Applications |
|
C11A |
04 - 1672 - 01C |
Street Box Installations – using half height boxes |
|
C12 |
91 - 0060 - 01E |
Water Main Dog Legs – Made of Flanged DICL & Flanged MSCL |
|
C13 |
91 - 0060 - 02B |
Water Main Dog Legs – Made of Restrained Joint DICL or PE |
|
C14 |
96 - 0085 - 01B |
DN63mm Polyethylene (PE) Mains (Laid in Cul De Sacs & Restricted Areas ONLY) Typical Layout of Main and Water Connections |
|
C15 |
96 - 0085 - 02B |
DN63mm Polyethylene (PE) Main Offtakes (Laid in Cul De Sacs & Restricted Areas ONLY) Use for Non-Live (Dry) Tappings Only |
|
C16 |
02 - 0155 - 01A |
DN63mm Polyethylene (PE) Mains off Existing Mains (Laid in Cul De Sacs & Restricted Areas ONLY Used for Live (Wet) Tappings Only |
|
C17 |
91 - 0061 - 01F |
Indicator Posts and Signs |
| |
|
|
|
SECTION D * |
ALLOCATION OF SPACE FOR SERVICES |
|
D |
|
Section D Cover Sheet |
|
D1 |
91 - 0084 - 01C |
Allocation of Space for Services in Land Divisions – Refer “Service in Streets Code” |
|
D2 |
2006 - 02987 Rev 2 |
Allocation of Space for Services in Land Divisions – Allotments 12 meters and above wide |
|
D3 |
2006 - 02988 Rev 2 |
Allocation of Space for Services in Land Divisions (with Recycled Water) – Allotments Less than 12 meters wide |
| D4 |
2006 - 02989 Rev 1 |
Allocation of Space for Services in Land Divisions (without Recycled Water) – Allotments Less than 12 meters wide |
|
D5
|
2009 - 31260 Rev 2 |
Allocation of Space for Services in Land Divisions (with Recycled Water) with light poles located on boundary – Allotments Less than 8 meters wide |
| |
|
|
|
SECTION E * |
WATER CONNECTIONS (divided into SET - E1 and SET - E2) |
|
E |
|
Section E Cover Sheet |
|
E1 |
96 - 0080 - 01D |
Water Connections - General Instructions and Comments |
|
E2 |
91 - 0089 - 02H |
Laying Details for PE Water Connections (DN20 Meters) - PE Mechanical Couplings off New Mains up to DN375 |
|
E3 |
91 - 0089 - 03G |
Laying Details for PE Water Connections (DN20 Meters) - Tita Brass Mechanical Couplings off New Mains up to DN375 |
|
E4 |
91 - 0089 -- 05G |
Laying Details for PE Water Connections (DN20 Meters) - Electrofusion Couplings off New Mains up to DN375 |
|
E5 |
91 - 0063 - 02B |
Laying Details for DN25 PE Water Connections (DN25 Meters) - off New Mains up to DN375 |
|
E6 |
91 - 0065 - 02B |
Laying Details for DN40 PE Water Connections (DN32 Meters and DN40 Meters) - off New Mains up to DN375 |
|
E7 |
91 - 0066 - 02C |
Laying Details for DN50 Water Connections (using DN63 PE) off New Mains up to DN375 |
|
E8 |
91 - 0091 - 01G |
Tapping into Charged Mains (Wet Tappings) Laying Details for PE Water Connections (DN20 Meters) off Existing Mains up to DN375 |
|
E9 |
94 - 0040 - 02B |
Tapping into Charged Mains (Wet Tappings) Laying Details for DN25 PE Water Connections off Existing Mains up to DN375 |
|
E10 |
94 - 0041 - 02B |
Tapping into Charged Mains (Wet Tappings) Laying Details for DN40 PE Water Connections off Existing Mains up to DN375 |
|
E11 |
94 - 0042 - 02B |
Tapping into Charged Mains (Wet Tappings) Laying Details for DN50 PE Water Connections off Existing Mains up to DN375 |
|
E12 |
2007 - 00679 Rev 3 |
DN20 Dual Check Water Meter Assemblies for Installation on Inlet risers Having Loose Jumper Valves |
|
E13 |
2007 - 00680 Rev 4 |
DN20 Dual Check Water Meter Assemblies for Installation on Inlet risers Having Ball Valves |
|
E14 |
2007 - 00737 Rev 1 |
DN25 Water Meter Assemblies Installation Details (Elster Above Ground Meters) |
|
E15 |
2007 - 00738 Rev 1 |
DN32 Water Meter Assemblies Installation Details (Elster Above Ground Meters) |
|
E16 |
2007 - 00739 Rev 1 |
DN40 Water Meter Assemblies Installation Details (Elster Above Ground Meters) |
|
E17 |
2007 - 00756 Rev 4 |
DN50 Water Meter Assemblies Installation Details From 2007 (Flowstar M Above Ground Meters) |
|
E18 |
91 - 0085 - 01F |
DN80, DN100 and DN150 Water Connections Layout and Fittings Schedule for Above Ground Turbine Flow Water Meters |
|
E19 |
2005 - 01172A |
DN80, DN100, DN150 and DN200 Water Connections Layout and Fittings Schedule for Above Ground Mag Flow Water Meters |
|
E20 |
99 - 0145 - 01C |
DN25 and DN40 Water Meter Connections - Manifold Assembly for DN20 Meters |
|
E21 |
2006 - 00466 Rev 1 |
PE Water Connections Below Ground Meter Installation DN20 Water Meters |
|
E22 |
2007 - 02999 Rev 1 |
DN50 Manifold Assembly DN25 Water Meters (for Industrial/Commercial Installations only) |
|
E23 |
2009-30411-01 Rev 3 |
Drinking Water to Recycled Water Temporary Connection Pipe Layout |
|
E24 |
2009-30411-01 Rev 2 |
Drinking Water to Recycled Water Temporary Connection Location |
| |
|
|
|
SECTION F * |
FIRE SERVICES |
|
F |
|
Section F Cover Sheet |
|
F1 |
91 - 0068 - 01F |
Laying Details for Pillar Fire Hydrants off New Mains up to DN375 |
|
F2 |
91 - 0068 - 02D |
Laying Details for Fire Services off Mains up to DN375 |
|
F3 |
91 - 0068 - 03D |
Laying Details for Temporary Fire Hydrant Ends for DN100 to DN375 Mains using Fabricated Flanged MSCL Extension Pipes, Flange/Spigot DICL or PE Extension Pipes |
|
F4 |
91 - 0068 - 04C |
Laying Details for Temporary Fire Hydrant Ends using DICL Pipe with Restrained Joint Rings for DN100 to DN375 Mains |
|
F5 |
91 - 0068 - 05A |
Laying Details for Fire Hydrant Ends, Permanent Fire Hydrant Ends for DN100 to DN375 Mains and Temporary Fire Hydrant Ends for DN100 to DN375 Mains - where Main WILL NOT be in Service |
|
F6 |
2006 - 00467 Rev 1 |
Fire Hydrants, Installation of Blue Reflectors and Painting of Road Markings |
| |
|
|
|
SECTION G * |
STRUCTURES |
|
G |
|
Section G Cover Sheet |
|
G1 |
2007 - 00700 Rev 3 |
PRV in Cabinet Sheet 1 - Typical Arrangement for up to DN100 Mains |
|
G2 |
2006 - 02710 Rev 4 |
PRV in Cabinet Sheet 2 - Typical Arrangement for up to DN100 Mains |
|
G3 |
2007 - 00702 Rev 4 |
PRV in Chain Mesh Cage Sheet 1 - Typical Arrangement for DN100, DN150 and DN200 Mains |
|
G4 |
2007 - 00701 Rev 4 |
PRV in Chain Mesh Cage Sheet 2 - Typical Arrangement for DN100, DN150 and DN200 Mains |
| |
|
|
|
SECTION H * |
CORROSION PROTECTION |
|
H |
|
Section H Cover Sheet |
|
H1 |
94 - 0031 - 01C |
Corrosion Protection for DN20 and DN25 Copper Connections |
|
H2 |
94 - 0031 - 02C |
Corrosion Protection for DN40 Copper Connections |
|
H3 |
94 - 0031 - 03C |
Corrosion Protection for DN50 Copper Connections |
|
H4 |
94 - 0031 - 04C |
Corrosion Protection for PE Connections (DN20 Meters) off UPVC, CICL, PE and AC Mains and off DICL Mains (Using Pretapped Connectors) |
|
H5 |
94 - 0031 - 05B |
Corrosion Protection of or PE Connections (DN20 Meters) off DICL Mains (Using Tapping Saddles) and off MSCL Mains |
|
H6 |
94 - 0043 - 01A |
MSCL Dog Legs Cathodic Protection |
|
H7 |
94 - 0044 - 01A |
DICL Dog Legs Cathodic Protection |
| |
|
|
|
SECTION J |
WATER SUPPLY DESIGN SYMBOLS |
|
J |
|
Section J Cover Sheet |
|
J1 |
96 - 0086 - 01A |
Legend of Fitting Symbols |
| |
|
|
|
SECTION K |
RECLAIMED WATER MAINS |
|
K |
|
Section K Cover Sheet |
|
K1 |
02 - 0071 - 01 |
Reclaimed Water Mains |
|
K2 |
02 - 0072 - 01 |
20mm Reclaimed Water Meter Assembly Installation Details (Above Ground Meters) |
|
K3 |
02 - 0073 - 01 |
Laying Details for DN20 Copper Reclaimed Water Connections from New Reclaimed Water Mains up to DN375 |
|
K4 |
02 - 0074 - 01 |
Laying Details for PE Reclaimed Water Connections (20mm Meters) using Mechanical Couplings from New Reclaimed Water Mains up to DN375 |
|
K5 |
04 - 1179 - 01 |
Retro fitting of air bleed assembly |
|
K6 |
2005 - 01143 |
Laying Details for PE Reclaimed Water Connections using below ground water meters (20mm meters) |
|
K7 |
2005 - 1171B |
DN20 Reclaimed Water Meter Relocations |
| |
|
|
|
SECTION L * |
MAINTENANCE / REPAIRS |
|
L |
|
Section L Cover Sheet |
|
L1 |
02 - 0120 - 01C |
Repairing DN20 Water Connections |
|
L2 |
02 - 0120 - 02A |
Repairing DN20 Copper Water Connections Substitution of Flared Nut with SA Water Stock Item number 4730 - 4967 |
|
L3 |
2005 - 0603B |
Water Connections Permanent Disconnections |
|
L4 |
2005 - 0602A |
DN20 Water Connections Removal of Meter - Temporary |
|
L5 |
04 - 1672 - 01B |
Replacement of Street Boxes |
|
L6 |
2005 - 01144 Rev 3 |
Dn20 and DN25 Water Meters, Meter relocations |
|
L7 |
91 – 0062 – 01H |
Laying Details for DN20 Copper Water Connections |
|
L8 |
91 – 0063 – 01i |
Laying Details for DN25 Copper Water Connections |
|
L9 |
91 – 0065 – 01H |
Laying Details for DN40 Copper Water Connections |
|
L10 |
91 – 0066 – 01H |
Laying Details for DN50 Copper Water Connections |
| L10A |
2007 – 01859 Rev 1 |
DN20 Water Meter Assemblies Inlet Riser and Meter Combinations (Above Ground Meters) |
|
L11 |
91 – 0087 – 01E |
DN20 Water Meter Assemblies Installation Details (Above Ground Meters) |
|
L12 |
2007 – 00681 Rev 1 |
DN20 Water Meter Assemblies Alteration - Installation of Outlet Riser with Back Flow Prevention - When Recycled Water Connection OR Rain Water Tank Is Installed |
|
L13 |
91 – 0087 – 02B |
DN25 Water Meter Assemblies Installation Details (Schlumberger DN25 Meters) |
|
L14 |
91 – 0088 – 01D |
Water Meter Assemblies for DN40 Water Connections Installation Details DN32 Water Meters (Kent PS32 Meters) Above Ground Meters |
|
L15 |
2007 – 00757 Rev 1 |
DN50 Water Meter Assemblies Installation Details (Woltex PS50 Meters) Above Ground Meters |
|
L16 |
96 – 0083 – 01B |
DN20 and DN25 Water Meter Assemblies Below Ground Water Meter Installations (using SA Water Meter Access Chambers) |
|
L17 |
96 – 0084 – 01C |
DN40 Water Meter Assembly Below Ground Water Meter Installations (using SA Water Meter Access Chambers) |
|
L18 |
96 – 0084 – 02A |
DN50 Water Meter Assembly Below Ground Water Meter Installations (using SA Water Meter Access Chambers) |
| |
|
|
|
SECTION M * |
HISTORICAL INFORMATION ONLY |
|
M |
|
Section M Cover Sheet |
|
M1 |
91 - 0062 – 01H |
Laying Details for DN20 Copper Water Connections for Mains up to DN375 |
|
M2 |
91 - 0063 – 01i |
Laying Details for DN25 Copper Water Connections for Mains up to DN375 |
|
M3 |
91 - 0065 – 01H |
Laying Details for DN40 Copper Water Connections for Mains up to DN375 |
|
M4 |
91 - 0066 – 01H |
Laying Details for DN50 Copper Water Connections for Mains up to DN375 |
|
M5 |
91 - 0087 – 01E |
DN20 Water Meter Assemblies Installation Details for Above Ground Meters |
|
M6 |
2007 – 00681 Rev 1 |
DN20 Water Meter Assemblies Alteration – Installation of Outlet Riser with Back Flow Prevention – When Recycled Water Connection or Rain Water Tank is Installed |
|
M7 |
91 - 0087 – 02B |
DN20 Water Meter Assemblies Installation Details for Above Ground Meters (Schlumberger DN25 Meters) |
|
M8 |
91 - 0088 – 01D |
Water Meter Assemblies for DN40 Water Connections Installation Details DN32 Water Meters (Kent PS32 Meters) (for Above Ground Meters) |
|
M9 |
2007 – 00757 Rev 1 |
DN50 Water Meter Assemblies Installation Details (Woltex Above Ground Meters) |